Try itRead-only telemetry tap for IEC-104, DNP3, and IEC 61850 MMS substations — monitor SCADA traffic without any control surface.
What it does
Connects to utility telecontrol systems as a read-only data tap using three protocols: IEC 60870-5-104 (RTU telemetry and general interrogation), DNP3/IEEE 1815 (outstation integrity polls), and IEC 61850 MMS (IED logical device and data-attribute reads). Each protocol exposes a doctor-first workflow (link status → interrogate → targeted reads). The base cross-protocol brain (dataflow diagnosis, alarm analysis, data-quality scorecards, OEE, asset inventory, compliance self-assessment) runs on the same server. GOOSE and Sampled Values are not supported — only MMS reads. All tools carry risk=low; the design guarantee is that no control tools exist in this edition.
When to use it
- Monitor substation telemetry without touching control systems
- Query IEC-104 general interrogation or DNP3 integrity polls
- Browse IEC 61850 IED logical devices and read data attributes
- Analyze protection Sequence-of-Events for selectivity issues
The skill document
iaiops-energy — substation / utility telecontrol data tap (变电 / 电力)
The energy edition of Industrial-AIOps as one governed MCP server: read-only
connectors for the three utility telecontrol protocols — IEC 60870-5-104,
DNP3 / IEEE 1815, IEC 61850 MMS — built on the base iaiops core, plus the
base cross-protocol brain mounted onto the same server. Every tool runs
through the iaiops governance harness (audit / budget / risk-tier); startup
refuses to serve any tool missing the _is_governed_tool marker.
Monitor-direction ONLY — deliberately. No control/operate surface exists in this edition: no DNP3 CROB or analog-output, no setpoints, no select-before-operate, no IEC-104 command ASDUs (C_SC / C_DC / C_SE), no IEC 61850 control model. This is not a gated write — the tools simply do not exist, so an agent cannot be talked into operating a breaker. 未经授权勿对生产控制系统写入。
When to route here
Task mentions: IEC 60870-5-104 / IEC-104 / 104规约 / general interrogation / 总召 / IOA, DNP3 / IEEE 1815 / outstation / integrity poll / Class 0/1/2/3, IEC 61850 / MMS / IED / logical device / logical node / data attribute / functional constraint, substation / 变电站 / RTU / telecontrol / SCADA gateway, energy / power / utility telemetry, 遥测 / 遥信 / 电力监控.
Explicitly out of scope: IEC 61850 GOOSE and Sampled Values (layer-2 pub/sub — not supported; MMS client reads only), protection-relay settings changes, any control/operate action.
Factory / building / process protocols route elsewhere: OPC-UA, Modbus,
Siemens S7, Mitsubishi MC, MTConnect, MQTT/Sparkplug B, EtherNet/IP, EtherCAT,
SECS/GEM, PROFINET, HART-IP, BACnet → use the base iaiops server
(pip install iaiops, then iaiops-mcp), not this one.
Install & run
pip install 'iaiops-energy[energy]' # all three protocols
pip install 'iaiops-energy[iec104]' # or per-protocol extras:
pip install 'iaiops-energy[dnp3]' # [iec104] / [dnp3] / [iec61850]
iaiops-energy-mcp # brain + energy tools over stdio
iaiops-energy pulls in the base iaiops package (shared core) automatically.
Protocol client libs are lazy optional extras — a missing lib degrades to a
teaching error naming the exact pip install, not a crash. Targets live in
~/.iaiops/config.yaml (override path via IAIOPS_CONFIG):
protocol: iec104|dnp3|iec61850, host, port, plus common_address /
unit_id as the protocol needs. Credentials go to the encrypted secret store,
unlocked via IAIOPS_MASTER_PASSWORD — never into config or chat.
MCP client config (stdio):
{
"mcpServers": {
"iaiops-energy": {
"command": "iaiops-energy-mcp",
"env": {
"IAIOPS_CONFIG": "/etc/iaiops/config.yaml",
"IAIOPS_MASTER_PASSWORD": ""
}
}
}
}
Every tool takes an optional endpoint selecting a named target from that
config; omitted, the sole/default target of the protocol is used.
Tools by protocol (all [READ][risk=low])
IEC 60870-5-104 (c104; RTU / substation telemetry — 遥测遥信)
iec104_connection_info— connect and report link status + discovered stations (common addresses) — the IEC-104 doctor stepiec104_interrogate— general interrogation (总召): all monitored points of one station by ASDU common address, with type / quality / timestampiec104_read_point— read ONE monitored point by information-object address (IOA)
DNP3 / IEEE 1815 (pydnp3; outstation monitoring)
dnp3_link_status— bring the DNP3 master online and report link / outstation status — the DNP3 doctor stepdnp3_integrity_poll— Class 0/1/2/3 integrity poll: the outstation's database grouped by measurement type (binary / analog / counter …)
IEC 61850 MMS (pyiec61850; substation IED reads — linux-only wheel)
iec61850_device_directory— list the IED's logical devices (optionally their logical-node children) — the IEC 61850 doctor stepiec61850_browse— browse immediate model children under a reference (LD / LN / DO)iec61850_read— read one data attribute by object reference + functional constraint (e.g.LD0/MMXU1.TotW.mag.f, FCMX)
Substation intelligence (pure analysis — no live I/O)
substation_event_analysis— Sequence-of-Events (SOE) protection-trip / selectivity analysis: feed injected relay pickups/trips + breaker open/close + lockouts ({ref, timestamp, type}) and it decides what tripped and whether protection coordinated — selective trip vs non-selective backup operation vs breaker failure, cite-first, monitor-only(变电事件序列/保护选择性分析:判定 跳闸与保护配合是否正确——选择性跳闸/后备越级动作/断路器失灵;纯分析、只读, 不做任何 live I/O)
Cross-protocol brain (mounted from the base iaiops package)
The base brain tools register onto this server too — diagnostics
(diagnose_dataflow, alarm_bad_actors, tag_health, historian_health,
data_quality_scorecard, downtime root-cause), analytics (OEE / downtime,
monitor_changes), asset inventory + unified asset model / alias governance,
and compliance self-assessment (防护指南 / 等保 2.0 / IEC 62443) — plus
protocols_supported for the capability map. Same governance harness; see the
base iaiops skill for the full brain reference.
Supported versions (honest matrix)
| Protocol | Lib pin (this release) | Spec / transport | Verification status | CI |
|---|---|---|---|---|
| IEC 60870-5-104 | c104>=2.0,<3 | IEC 60870-5-104 over TCP/2404 | verified (monitor path) — real client↔server round-trip vs an in-process c104 server (tests/test_iec104_live.py, passes in a Linux container): general interrogation returns seeded points, bad IOA → no fabricated value, no control ASDU issued; skips on macOS (no c104 wheel). Live RTU 待核实 | ✅ runs every push |
| DNP3 / IEEE 1815 | pydnp3>=0.1,<1 | IEEE 1815, TCP; monitor direction only | verified (monitor path) — real master↔outstation round-trip vs a live opendnp3 outstation; physical RTU 待核实 | ✅ runs every push ¹ |
| IEC 61850 MMS | pyiec61850>=1.5.2a1,<2 (linux-only wheel) | MMS over ISO-on-TCP/102; no GOOSE/SV | verified (monitor path) — real client↔server round-trip vs an in-process libiec61850 MMS server; physical IED 待核实 | ✅ runs every push |
¹ All three monitor paths are CI-gated (since 0.1.11), and a skipped live test now
fails the build — a skip and a pass look identical in a green badge, which is how the
DNP3 gap survived. This block used to say DNP3 and IEC-61850 were not covered by CI.
IEC-61850 had in fact been running there for some time and nobody rechecked; DNP3 was
believed unbuildable on hosted runners, which was wrong — opendnp3 compiles clean and the
2019 binding layer needed three mechanical fixes, scripted in scripts/build_pydnp3.sh.
pydnp3 ships no wheel (opendnp3 is built from source by that script);
pyiec61850 is a linux-only SWIG wheel — both protocols no-op with a teaching
error elsewhere. CI coverage is level ② (real library, loopback), never level ③.
Anything not yet proven against real gear stays marked 待核实 — do not claim otherwise.
Doctor-first workflow
protocols_supported— see what this server exposes and what's configured.- Prove the link with the protocol's cheap status tool before any deep
read:
iec104_connection_info/dnp3_link_status/iec61850_device_directory. - Only then interrogate:
iec104_interrogate/dnp3_integrity_poll/iec61850_browse→ targeted reads (iec104_read_point/iec61850_read). - Feed results to the brain (e.g.
diagnose_dataflowfor "no data",data_quality_scorecardfor fleet trust,alarm_bad_actorsfor floods).
Safety
Read-only edition: zero write/control tools, so there is nothing to gate — the
strongest guarantee available. All tools are risk=low, audited, and
budget-tracked; errors return the canonical {error, hint} shape. Never point
this at production telecontrol gear without authorization; interrogations and
integrity polls do generate real traffic on the operational link. No tool
returns secrets.
Questions people ask
- Does this tool support any write or control operations?
- No. This is a deliberately monitor-only edition. No DNP3 CROB, no setpoints, no IEC-104 command ASDUs (C_SC/C_DC/C_SE), no IEC 61850 control model. The tools simply do not exist — there is nothing to gate.
- Can it perform general interrogation on an IEC-104 RTU?
- Yes. The iec104_interrogate tool triggers a general interrogation (总召) for all monitored points at one station's common address, returning type, quality, and timestamp per point.
- Does iaiops-energy support GOOSE or Sampled Values?
- No. GOOSE and Sampled Values are layer-2 pub/sub protocols; only MMS client reads are implemented. IEC 61850 support is limited to logical-device directory, model browsing, and data-attribute reads.
Related skills
Join video meetings as a voice bot, visual avatar, or avatar with live screen sharing.
End-of-day options analytics ranked against each ticker's own history: IV rank, put/call percentile, skew, max pain, and unusually active contracts.
Measure whether a transformation changed your growth engine or just added a one-time bump.
Diagnose which mental domain is holding you back before choosing a cognitive intervention.
Turn China 3C launch inputs into executable routes, messaging, channel actions, risk checks, and review decisions.
More from zw008
Browse all skillsOperate VMware VMs, deployments, clusters, guest tasks, and alarms with plan and rollback support.
Inspect VMware health, inventory, alarms, events, and performance without changing infrastructure.
Query Aria Operations metrics, alerts, capacity forecasts, anomalies, and reports from CLI or MCP.
Manage AVI services and pools, and diagnose AKO ingress, sync, certificates, analytics, and health.
Manage Supervisor Namespaces and TKC cluster lifecycles in vSphere Kubernetes Service.
Manage NSX segments, gateways, routing, IP pools, health checks, and connectivity diagnostics.